Preview

Metrologiya

Advanced search
Open Access Open Access  Restricted Access Subscription Access

Consider the nonuniformity of the electromagnetic field when calibrating thin dipole and loop antennas in electromagnetic field source based on a four-wire transmission line

https://doi.org/10.32446/0132-4713.2021-1-60-74

Abstract

The influence of nonuniformity of electric and magnetic fields on the calibration accuracy of dipole and loop antennas in field sources based on four-wire transmission lines is theoretically investigated. The paper proposes to take into account the influence of the nonuniformity of the electromagnetic field of a four-wire source when calibrating thin dipole and loop antennas using the equivalence coefficients. The use of these coefficients, taking into account the distributions of the field in the source and the current on the antenna conductors, can significantly weaken the requirement for field uniformity when calibrating antennas. For some common types of antennas, formulas are derived for the equivalence coefficients in the approximation of a four-wire source by an infinite line. Approximation formulas, simplified for engineering calculations, are obtained.

About the Authors

V. I. Lukyanov
Russian Metrological Institute of Technical Physics and Radio Engineering (VNIIFTRI)
Russian Federation

Volemir I. Lukyanov 

Mendeleevo, Moscow region



M. V. Vasilyeva
Russian Metrological Institute of Technical Physics and Radio Engineering (VNIIFTRI)
Russian Federation

Mariya V. Vasilyeva 

Mendeleevo, Moscow region



References

1. Tishcenko V. A., Tokatly V. I., Luk’yanov V. I., Measurement Techniques, 2001, vol. 44, no. 8, pp. 862–866. https://doi.org/10.1023/A:1012912805203

2. Buzin ov V. S., Vasenkov L. V., Tokatly V. I., Izmeritel’naya tekhnika, 1990, no. 5, pp. 51–52 (in Russian).

3. Tishchenko V. A., Tokatly V. I., Lukyanov V. I., Measurement Techniques, 2012, vol. 55, no. 9, pp. 965–970. https://doi.org/10.1007/s11018-012-0083-z

4. Tishchenko V. A. et al., Creation and improvement of the reference base in the field of radio frequency electromagnetic measurements, Mendeleevo, VNIIFTRI Publ., 2013, pp. 20–72 (in Russian).

5. Morioka T., IEEE Transactions on Instrumentation and Measurement, 2011, vol. 60, no. 7, рр. 2709–2714. https://doi.org/10.1109/TIM.2010.2095545

6. Moirioka T., Kurokawa S., Toba Y., Ichijyo J., 2016 URSI Asia-Pacific Radio Science Conference (URSI AP-RASC), Seoul, 2016, pp. 1–3. https://doi.org/10.1109/URSIAP-RASC.2016.7883538

7. Beiranvand R., Review of Scientific Instruments, 2013, vol. 84, no. 7. https://doi.org/10.1063/1.4813275

8. Land S. O., Perdriau R., Ramdani M., IEEE Transactions on Electromagnetic Compatibility, 2017, vol. 59, no. 6, pp. 2042–2045. https://doi.org/10.1109/TEMC.2017.2691800

9. Fradin A. Z., Antenno-fidernye ustrojstva. Uchebnoe posobie dlya vuzov svyazi, Moscow, Svyaz’ Publ., 1977, pp. 43, 83, 126 (in Russian).

10. Tokatly V. I., Design of an electrodynamic model of a variable electric field meter with dipole antenna, Measurement Techniques, 1992, vol. 35, no. 6, pp. 715–722. https://doi.org/10.1007/BF00977066.


Review

For citations:


Lukyanov V.I., Vasilyeva M.V. Consider the nonuniformity of the electromagnetic field when calibrating thin dipole and loop antennas in electromagnetic field source based on a four-wire transmission line. Metrologiya. 2021;(1):60-74. (In Russ.) https://doi.org/10.32446/0132-4713.2021-1-60-74

Views: 379


ISSN 0132-4713 (Print)
ISSN 2712-9071 (Online)